Điều hòa Tủ đứng Daikin FVY100LAVE3 / R100LUV15(Y15)
Loại Tủ đứng 1 chiều
Công suất 36,100 BTU/h
Gas R22 - Xuất xứ Thái Lan
Phù hợp với Tòa nhà, Nhà máy, Khu công nghiệp, Nhà hàng, ...
Đặc điểm dàn nóng Điều hòa Daikin Tủ đứng FVY100LAVE3:
Compact and Quiet |
Quiet Operation |
|
Wide inlet fan |
|
Fully-shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high airflow volume and quiet operation with minimal turbulence. | |
Super aero grille |
|
To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air. | |
Scroll compressor for quiet operation
|
|
Smooth running, minimal vibration, and low operation sound. |
Compact |
|
Slim and low-profile design outdoor units |
|
These compactly designed outdoor units have an interior layout optimised for the smooth flow of air. | |
Reduced weight |
|
The lightweight design makes delivery and installation easier than ever before. | |
Operation sound |
|
|
Powerful |
|
The use of a "receiver" enhances refrigerant control |
|
Instead of using an accumulator to adsorb excess refrigerant, Daikin outdoor units have an in-pipe receiver located away from the compressor. By preventing the return of liquid to the compressor, this receiver enhances reliability. | |
Defrost control delivers powerful heating in extremely cold climates |
|
To optimise heating performance, temperature differences between the air in the indoor/outdoor heat exchanger and the intake air are monitored and accurate adjustments made to provide the best operating parameters, such as activating the defrost mode and minimising indoor temperature drops caused by frost. For example, if the outdoor temperature falls to -1.5 ℃, the integral heating capacity is raised about 20%. | |
Suited for year-round cooling applications |
|
Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. • Heat pump/RY71–140LU: possible up to -5℃ |
|
Installation and maintenance |
|
Pre charged for up to 30 metres |
|
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. | |
4-direction piping offers greater layout freedom |
|
Piping can be run from the front, bottom, right or rear surface according to how the unit is installed. | |
Facilitates pump down |
|
A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or the layout modified. This lessens the environmental impact by preventing the release of refrigerant into the atmosphere. | |
Low gas level detection function |
|
Effective gas monitoring reduces the labour required for operation, maintenance, and repairs. |
Durability |
|
Anti-corrosion treated heat exchange fins |
|
The outdoor unit's heat exchanger fin has been specially pretreated with an acrylic PE coating to improve their resistance to salt corrosion and atmospheric pollution. |