Chi tiết sản phẩm
A hybrid wired and wireless control panel, 4 wired loops, 16 wireless zones, 2 sections, 4 outputs, 15 user codes, a 127 event memory, security level 2 according to EN 50131, 230V AC, 500 mA power source, space for a backup battery
In the plastic box of the JA-63 there is a power supply and space for the backup battery with a capacity of 1.3 or 2.6 Ah.
The JA-63 motherboard are four input terminals for wire loops (with the option of single or double balancing). If the control panel is equipped with a radio module (JA-63KR), it has 16 wireless zones for JA-60 series detectors (2 detectors can be enrolled to each zone). You can also use up to 8 wireless keypads or remote controls, JA-60A wireless sirens and UC-2XX wireless output modules. To extend the system's control panel, it can be enrolled to another JA-6x sub-type wireless control panel. This superior system acquires information about events from the slave sub-panel control panel.
When fully configured (installation of all modules) you can have a 16 zone 4 loop wireless + wired system. The control panel can be divided into two user-programmable independent sections with shared parts (split mode control panel).
The panel can be fitted with two types of communicators:
- The JA-65X communicator transmits voice messages, SMS messages through an SMS server, communicates with ARCs and allows remote access from an installer's or user's PC (using ComLink SW and a JA-60U).
- The JA-60GSM communicator sends SMS messages, calls predefined numbers and plays audible warnings, communicates with two ARCs, allows remote access from a phone keypad and settings via a web site. Allows for telephone connection to the building, as well as sending and receiving SMSes, and Internet access. You can also control two devices in the building - such as heating and air conditioning.
Awards
The JA-63 PROFI alarm system has won the following awards: |
|
|
SecuTech Innovations Award 2004 |
Golden Plaque Coneco 2004 |
Specifications
control panel power |
230 V / 50 Hz, max 0.1 A, Protection class II |
Backup battery |
12 V, 1.3 Ah or 2.6, the system automatically recharges the battery and checks its condition, normal battery lifetime is about 5 years |
Backup power output |
maximum continuous load 0.4 A, intermittent load up to 1.2 A for 15 min |
Control panel standby consumption |
30 mA, JA-60E = 25 mA |
number of wireless zones ** |
16 (each can be assigned to up to 2 wireless detectors), i.e. up to 32 detectors |
number of wired zones |
4, optional types of loop activation (double balanced, single balanced, normally closed loop) |
relay output |
contact 60 VDC / 1 A |
optional outputs |
PGX, PGY max 0.1 A, switching to GND, programmable function |
siren output max |
load 0.7 A |
event memory |
last 127 events with date and time |
operating frequency ** |
433.92 MHz |
level of security |
2 according to EN50131-1, EN 50131-6 |
designed for environments |
class II. (-10 to +40 ° C) according to EN 50131-1 |
Also meets: |
Radio Emissions (EMC)
Electrical Safety |
ETSI EN 300220 ETS 300683 EN 60950 |
phone dialer * |
2 voice alarm messages to 4 tel. numbers (can be assigned to different events) SMS alarm messages - through Jablotron digital transmission to an ARC modem communications with remote computer Complies with EN 301 437 |
* for CPs equipped with a telephone communicator ** valid for CPs equipped radio modules type R |