Power Source
|
230 VAC, 50/60 Hz
|
Power Consumption
|
850 W (with rated output signal), 380 W (according to EN60065)
|
Rated Output
|
360 W
|
Frequency Response
|
50 Hz - 20 kHz, ±3 dB (at 1/3 rated output)
|
Distortion
|
0.7 % or less (at rated output, 1 kHz)
|
S/N Ratio
|
85 dB or more
|
Input
|
External amplifier input: 100 V line, removable terminal block (14 pins)
|
Output
|
Speaker output 1 - 2: Max. (360 W) per output
Speaker output 3 - 6: Max. (120 W) per output
Speaker output 1 - 6: Total within 360 W, removable terminal block (14 pins)
Allowable minimum load: 500 Ω (20 W) at 100 V line for speaker line failure detection
Direct output: Direct output from internal or external amplifier, removable terminal block (16 pins)
|
VM Link
|
Input: Connecting the VM-3240VA or VM-3360VA, RJ45 female connector
|
Output: Connecting the VM-3240E or VM-3360E, RJ45 female connector
|
Maximum distance: 800 m (874.89 yd)
|
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
|
EXT PA Link
|
Connecting the VP-2421, RJ45 female connector
|
Maximum distance: 5 m (16.4 ft)
|
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
|
General Control
|
Input 1 - 8: No-Voltage make contact input, open voltage: 24 VDC, short-circuit current: 2 mA or less, removable terminal block (14 pins)
Output 1 - 8: Isolated open collector output, withstand voltage: 30 VDC, operating current: 10 mA or less, removable terminal block (14 pins)
|
Emergency Control
|
Input 1 - 5: No-Voltage make contact input, open voltage: 24 VDC, short-circuit current: 2 mA or less, RJ45 female connector
Input 6: Isolated voltage input, Inactive: -24 V ±20 %, Active: +24 V ±20 %, RJ45 female connector
Status out: Relay contact output, withstand voltage: 40 VDC, operating current: 2 - 300 mA, RJ45 female connector
|
ATT Control
|
Relay contact 1-6, 125 VAC or 30 VDC, total under 5 A, removable terminal block (16 pins)
|
Power Input/Output
|
Power in: Connecting the VX-2000DS only (operating range: 20 - 40 VDC)
|
PS out: 28 VDC/24 A
|
M4 screw terminal, distance between barriers: 11 mm (0.43\')
|
Output
|
24 VDC, Maximum feeding current 0.3 A
|
Ds Link
|
Connecting the VX-2000DS, RJ45 female connector
|
Maximum distance: 5 m (16.4 ft)
|
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
|
Finish
|
Panel: Aluminum, hairline, black
|
Case: Surface-treated steel plate, black, paint
|
Dimensions
|
482 x 132.6 x 407 mm
|
Weight
|
19 kg
|
Accessory
|
Power cable (2 m (6.56 ft)) …1, Link cable (3 m (9.84 ft)) …2, Plastic foot …4, Plastic foot mounting screw …4, Removable terminal plug (14 pins) …3, Removable terminal plug (16 pins) …1
|