Cáp mạng Dintek CAT.6 UTP (1101-04023, 100 mét/thùng)
Part Number: 1101-04023
- Cáp mạng CAT.6 UTP Dintek 4-pairs, 23AWG, 100m/thùng.
- Khoảng cách truyền tín hiệu: 100 mét.
Features
- Conductor sizes for Cat.6 are set at 23AWG
- By keeping the gauge size of the conductor larger, there is less heat generation caused and less drop of voltage over distance
- Capable of handling the latest version of power over ethernet
- Cable has been tested over 500Mhz and has shown performance testing results allowing 10Gbit Ethernet transmission up to a length of 70mtrs
Standards Conformance
- ACMA approved to AS/CA S008
- ISO/IEC11801 2nd edition CLASS E
- ANSI/TIA-568-2.D standard
- CENELEC EN 50173-1, CENELEC
- PoE++ & 4PPoE - IEEE 802.3bt level 3 & 4
- Flame Rated: CM
Independent Verified Certifications
- Verified to ANSI/TIA-568-2.D Cat.6 102661868CRT-001b
- ACMA approved to AS/CA S008
Specifications
Construction |
Conductor |
Material |
Bare Copper |
Wire Size |
23AWG |
Insulation |
Material |
PE |
Thickness |
Nominal: 1.011 mm |
Colors |
Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown |
Unaged Elongation(%) |
Min. 300% |
Unaged Tensile Strength |
Min. 1.683 Kgf/mm² |
Jacket |
Material |
Flame Retardant PVC |
Thickness |
0.5 ± 0.02 mm |
Diameter |
6.0 ± 0.2 mm |
Color |
Gray (assorted upon request) |
Fire Rated Class |
CM |
Physical Ranges |
Insulation |
Min. Tension Strength |
Before Aging: Min. 1.683 Kgf/mm² | After Aging: 75% before aging (100℃ X 48hrs) |
Min Elongation (%) |
Before Aging: 300% | After Aging: 75% before aging (100℃ X 48hrs) |
Jacket |
Min. Tension Strength |
Before Aging: Min. 1.407 Kgf/mm² | After Aging: 75% before aging (100℃ X 168hrs) |
Min Elongation (%) |
Before Aging: Min. 100% | After Aging: 50% before aging (100℃ X 168hrs) |
Dielectric Strength |
2500 VDC / 2 seconds |
Min. Bending Radius |
50 mm |
Max. Pulling Tension |
25 lbs |
Installation Temperature |
0℃ to +50℃ |
Operating Temperature |
-20℃ to +70℃ |
Electrical |
Conductor Resistance |
Max. 7.32 Ω/100m at 20℃ |
DC Resistance Unbalance |
Max. 2% |
Pair-to-Ground Capacitance Unbalance |
Max. 160 pF/100m |
Dielectric Strength of Insulation |
2500 V dc / 2 seconds |
Insulation Resistance Test |
Min. 5000 MΩ·Km |
Mutual Capacitance |
Max. 5600 pF/100m |
Impedance 1~100MHz |
100Ω ± 15% |
Impedance 100-250MHz |
100Ω ± 22% |