Conductor |
Material |
CCA (Copper content 22%–31%) |
Diameter |
0.57 mm ± 0.01 mm (0.0224'±0.0004') |
Wire Gauge |
23AWG |
Insulation |
Material |
HDPE |
Thickness |
0.21 mm (0.0083') |
Diameter |
1.02 mm±0.1 mm (0.0402'±0.004') |
Color |
Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
Separator |
Material |
PE |
Specification |
Translucent 4.5 mm × 0.4 mm (0.1772'±0.0157') |
Rip Cord |
Material |
Polyester |
Specification |
500D |
Sheath |
Material |
PVC |
Min. Average Thickness |
0.5 mm (0.0197') |
Diameter |
6.5 mm±0.3 mm (0.2559'±0.0118') |
Electrical |
Max. DC Resistance of a Single Conductor |
11.5 Ω/100 m |
Min. Insulation Resistance |
5000MΩ·km |
Max. DC Resistance Unbalance |
2% (pair intra), 4% (pairs inter) |
Dielectric Strength |
No breakdown with 1kV DC for 1 min |
Transmission |
Characteristic Impedance |
100 Ω ± 15 Ω |
Near End Cross Talk |
≥39.30 dB/100 m @250 MHz |
Max. Attenuation |
34.8 dB/100 m @250 MHz |
Return Loss |
≥17.3 dB/100 m @250 MHz |
Mechanical |
Tensile Strength |
Sheath≥13.5 MPa, insulation≥16 MPa |
Elongation at Break |
Sheath≥150%, insulation≥300% |
Installation Bending Radius |
>8 times of outer cable diameter |
Conductor Elongation at Break |
≥10% |
Environmental |
Shrinkage of Insulation |
≤5% |
Color Migration Resistance of Insulation |
No migration |
Sheath Tensile Strength and Elongation at Break after Aging |
≥12.5 MPa, ≥100% |
Low Temperature Bending Test |
No cracking after the test |
Heat Shock Test |
No cracking after the test |
Operation Temperature |
–20°C to +60°C (–4°F to 140°F) |
Installation Temperature |
0°C to +50°C (32°F to 122°F) |
Storage Temperature and Humidity |
–10°C to +40°C (14°F to 104°F), <60% (RH) |
Security |
Vertical Fire Propagation Test |
Comply with IEC 60332-1-2 |
Packaging |
Cable Length |
100.0 m (328.08 ft)±1 m (3.28 ft) |
Inner Carton Dimensions |
286 mm × 119 mm × 289 mm |
Net Weight |
3.2 kg ±0.3 kg (7.05 lb±0.66 lb) |
Gross Weight |
3.5 kg ±0.3 kg (7.72 lb±0.66 lb) |
Packaging Dimensions |
595 mm × 310 mm × 270 mm |
Compliance |
Executive Standards |
Q/DXJ 067-2019 |
Certification |
Certification |
CPR Eca |